The armature voltage dc governor, armature current exciter current Settings, explained

Dc governor armature voltage, current, the armature exciter current Settings are through the dial to the code switch set, SSD590P dc governor these parameters are through the menu to set, this also is the biggest difference between dc governor, software menu basic didn't change.

Below we explained to the armature voltage dc speed, current parameter set

Dc governor panel switch layout is introduced: panel six square metal film, from left to right, potentiometer is in the armature current one hundred a setting, armature current ten setting, armature current bytes setting, exciter current ten setting, exciter current bits set data, exciter current a decimal point value. The right VA CAL four dial the code switch is used to set the armature current, dial the code switch play in the right of the representative 1, playing in the position of the left 0 s position, armature voltage

Below we to dc motor model for Z4 132 1 of 11 KW motor, for example, the motor nameplate parameters are: the armature current 29.6 A, the armature voltage 440 V, exciter current 3.6 A, excitation voltage 180 V

According to the above parameters, we set the armature current of 29.6 (dc governor armature current no decimal point A, so we take rounding method, the corresponding dial set) code switch Settings are as follows: the armature current one hundred A square to the position of the potentiometer dial 0, armature current ten square potentiometer dial the position of the representative to 3, 30 A, armature current square potentiometer dial 0 bytes to the position of the armature current, so was set to 30 A;

Exciter current set method (only when governor excitation control options to the current control, this set is only available) : exciter current set to 3.6 A, the corresponding to dial the code switch Settings as follows: exciter current ten square potentiometer dial 0 to position, exciter current A square to the 3 position, potentiometer on behalf of 3 A, exciter current decimal point A square potentiometer dial 6 position, to represent 0.6 A, and add up to 3.6 A, this will be set for exciter current 3.6 A.

The armature voltage set methods: armature voltage for 440 V, according to the graph 2 armature voltage set table shows, we can choose the armature voltage setting is 425 V or 450 V (when governor opening of weak magnetic acc, please remember not armature voltage will set for 450 V the gear, the method is as follows, specific) from up to down, we in turn set switch position for 0010 (425 V) or 1100 (450 V), switch position from up to down as follows: left or so left (425 V), or right left right left (450 V).